THE FIREBOX
Steel at its core.
The fully welded 5 mm steel firebox has vermiculite lining and an insulated outer casing.

A wide view of the fire and steady wood-fired warmth.
Original price was: R33,030.00.R30,999.00Current price is: R30,999.00.
Save R2,031In stock Delivery ETA: 5–7 working days
See it in your space. Send a photo and measurements for a quote and a visual preview.
WhatsApp UsTHE FLAMM 950, BUILT IN
A fully welded 5 mm steel firebox, vermiculite lining and an insulated outer casing sit behind the simple black trim plate of the FLAMM 950 Single Sided Built-in Fireplace. The large glass door keeps the flames in view, so the fire becomes part of the room on every cold evening. Burn dry, seasoned hardwood, and lift out the cold ash with the ash pan.
Register the fireplace within 30 days of purchase for the five-year guarantee. Without registration, the cover is 12 months.
MAKE YOURSELF AT HOME
Find your favourite chair, watch the fire and stay a little longer. A simple built-in finish makes the warmth part of your room, ready for every cold winter evening.
Surround, hearth, flue and furnishings are not included. Have an accredited installer confirm the design and clearances.
BUILT FOR SLOWER EVENINGS
THE FIREBOX
The fully welded 5 mm steel firebox has vermiculite lining and an insulated outer casing.
THE HEAT
Maximum output is 16 kW, with 80% efficiency. Room size, insulation and ceiling height affect the warmth you feel.
THE EVERYDAY
Use dry, seasoned hardwood. Keep the door closed during normal use. Remove cold ash with the ash pan.
PLAN YOUR FIREPLACE
Product dimensions are not the opening size.
Allow for the recess air space, permanent airflow, hearth and flue route. Have an accredited installer confirm the full design on the actual unit before construction.
GOOD TO KNOW
Read your instruction manual before you plan the installation.
See also: FLAMM 950 Double Sided Fireplace on Log Base · FLAMM 950 Single Sided Fireplace on Log Base · FLAMM 950 Double Sided Built-in Fireplace
The fireplace includes one front trim plate, an insulated outer casing, a glass door with handle, vermiculite lining and an ash pan. The flue kit, hearth and surround are not included. Arrange installation with an accredited installer.
Nominal output is 13 kW and maximum output is 16 kW, with 80% efficiency. The Output Calculator uses 14.5 kW, the middle of the two. Room size, insulation and ceiling height affect the warmth you feel.
The body is 952 mm wide, 505 mm deep and 536 mm high. The front trim is 988 × 601 mm. Leave at least 200 mm of permanent free air space at the sides and above, and at least 50 mm at the back. These are air-space allowances, not a finished opening specification. Have your installer confirm the opening, ventilation, support and access.
Keep combustible materials at least 800 mm away and furnishings at least 1,000 mm away. Allow at least 1,200 mm to a combustible ceiling above the fireplace. Use a non-combustible constructional hearth at least 125 mm thick, extending at least 400 mm in front of the loading door. Your installer must confirm the full design and local requirements.
The top outlet takes a 150 mm flue. Its connection bore is 151.9 mm. The flue centre is 174.5 mm from the rear edge in the top view. Flue kits are quoted to suit the building. The fireplace needs its own chimney route; do not connect it to a flue serving another appliance.
An accredited installer must check the chimney condition, size, draw and cleaning access before connection. Have the chimney swept before use. Send us the proposed route and measurements for a flue and configuration quote. We do not provide installation services.
Yes. Provide permanent combustion air to the room. Your installer must size the vents for the room and fireplace output. Do not use an extractor fan in the same room or in a room that supplies its combustion air.
Use dry, seasoned hardwood with less than 20% moisture. Logs should be about 350 mm long or less. Split logs thicker than 80 mm. Do not burn coal, anthracite, treated timber or household waste.
Have the installation checked before use. Follow the small-fire and paint-curing sequence in the operating manual. Keep the room well ventilated during this process. Keep the door closed during normal use and use a fireguard when children are nearby.
Register the fireplace within 30 days of purchase for the five-year limited main-body warranty. Without registration, the warranty period is 12 months. Consumable parts, including glass, firebricks and seals, are excluded. Keep the purchase, installation and commissioning documents.
Yes. Send a photo and measurements for a product and flue configuration quote. Arrange installation with an accredited installer.
We often have stock of this unit. Fill in the form below and we will get back to in within the hour to let you know if it’s available
Would you like a PDF quote for this product? Simply provide us with your name and email and we will send you a quote ASAP.
Added to your cart